Welcome to Our Company
Dynamic Fatigue Testing Machine

Dynamic Fatigue Testing Machine

5000000 INR/Piece

Product Details:

  • Number of Specimens 24 specimens per test
  • Power Supply 220V AC, 50 Hz, single phase
  • Port Size Standard 1/4 inch
  • Hardness Shore A: 1090 (as per material)
  • Specimen Size 400 200 mm (max recommended)
  • Resolution 0.1 mm
  • Gas Pressure 0.50.7 MPa (compressed air required)
  • Click to view more
X

Dynamic Fatigue Testing Machine Price And Quantity

  • 1 Piece
  • 5000000 INR/Piece
  • 5000000.00 - 20000000.00 INR/Piece

Dynamic Fatigue Testing Machine Product Specifications

  • 220V
  • 50 Hz
  • 30100 mm adjustable
  • Floor-standing
  • Digital LCD screen
  • Approximately 90 kg
  • Up to 500,000 cycles or as set
  • 1200 mm
  • 20120 cycles/min (adjustable)
  • 10C to 40C
  • Up to 500 mm
  • Programmable cycles, automatic stop, safety enclosure
  • Semi-Automatic/Automatic
  • 0200 mm displacement
  • Designed for foam, mattress, and cushion fatigue
  • Standard 1/4 inch
  • 400 200 mm (max recommended)
  • Shore A: 1090 (as per material)
  • 24 specimens per test
  • Microprocessor based (automatic/manual switching)
  • 220V AC, 50 Hz, single phase
  • 1 sec
  • Foam, mattress, cushion durability/fatigue assessment
  • 0.1 mm
  • 0.50.7 MPa (compressed air required)
  • 1% of reading
  • RS232/CAN
  • 20%90% RH
  • Dynamic Fatigue Testing Machine
  • Industrial material testing

Dynamic Fatigue Testing Machine Trade Information

  • North America, Africa, Asia, Australia, South America, Eastern Europe, Western Europe, Middle East, Central America
  • All India

Product Description

Being a client centric organization, we are offering a wide array of Dynamic Fatigue Testing Machine. It is used to test foam fatigue by repeating indentation of a test piece. In addition to this, provided machine adjust the low platen automatically. Dynamic Fatigue Testing Machine is able to enable a solution for dynamic materials testing. It is retrofitted to a wide variety of testing systems from other providers. It is used to determine the durability of a material. 



Precision and Reliability for Material Fatigue Testing

Engineered for consistent and accurate fatigue measurements, this machine utilizes a heavy-duty frame and electro-mechanical actuator to perform demanding cyclic tests. It supports a wide range of specimen sizes and test strokes, making it suitable for evaluating the long-term performance and durability of various foam and cushion products used in mattresses and seating applications.


Advanced Control and User-Friendly Operation

With a microprocessor-based system, users can switch smoothly between automatic and manual test modes. The digital LCD display offers clear readings, while programmable cycles and an emergency stop enhance test flexibility and operator safety. Data is conveniently logged and exported via USB for efficient analysis and reporting.


Optimal Safety and Clean Operating Standards

Built-in safety features, including interlocks and overload protection, ensure secure operation during testing. Operating requirements include a vibration-free, dust-controlled indoor space, and the system maintains a low noise level, safeguarding both specimens and users. Floor-standing design and compact footprint simplify installation and usage in laboratories and production environments.

FAQ's of Dynamic Fatigue Testing Machine:


Q: How is the Dynamic Fatigue Testing Machine operated?

A: The machine operates via a microprocessor-based control system, allowing automatic or manual switching. Users set test parameters, specimen count, and cycle numbers through an intuitive interface, after which the electro-mechanical actuator performs the programmed fatigue tests.

Q: What types of materials can be tested using this machine?

A: This equipment is specifically designed for industrial fatigue assessment of foams, mattresses, and cushions. It can accommodate specimens up to 400 200 mm and test up to four samples simultaneously, making it versatile for varied material testing applications.

Q: When is data recorded and how can it be retrieved?

A: Data is logged continuously during each fatigue testing cycle by the in-built data logger. Upon completion, users can export test results quickly to a USB drive for further analysis and record-keeping.

Q: Where should this machine be installed for optimal performance?

A: For best results, install the machine indoors in a vibration-free, dust-controlled room. Maintaining an operating temperature between 10C and 40C and humidity levels from 20% to 90% RH ensures accurate and reliable results.

Q: What is the process for setting the test parameters and starting a test?

A: Operators select the number of cycles, adjust test speed (20-120 cycles/min), set test stroke (30-100 mm), and input specimen details through the LCD interface. After configuring parameters, the machine initiates the testing sequence, monitoring and recording data automatically.

Q: How does the safety system protect users and equipment?

A: Safety is ensured through an emergency stop button, safety interlocks, overload protection, and an enclosure around the test area. These features help prevent accidents and equipment damage during operation.

Q: What are the main benefits of using this fatigue testing machine?

A: Key benefits include highly accurate fatigue analysis, programmable cycles up to 999,999, rapid data export, quiet operation, and strong safety features. Its automated controls and robust construction reduce manual workload and improve productivity in industrial testing environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Fatigue Testing Machine' category



Back to top